MODEL: RG15090

Generac 150kW Standby Generator | Liquid-Cooled

★★★★★0.0 / 5No reviews yet

Generac 150kW Protector (RG15090): up to 150 kW on 3-phase natural gas from a turbocharged 8.9L V8 at 1,800 RPM, with a Power Zone 410 controller and 5-year limited warranty. Single-phase and 3-phase versions.

Priced per project

Send us your details and we will prepare a quote for your site.

Get a Free Quote Or call 1-844-443-6776

Free Delivery Available *

* Free shipping is available for generators and transfer switches installed by Platinum Electrical Contractors. To enable this option, please select Local Pickup / Installed by Platinum at checkout.
SKU PCG-10150 Categories , ,

Generac 150kW Protector Liquid-Cooled Standby Generator

The Generac 150kW Protector (RG15090) is the largest Protector generator we list. Its turbocharged and aftercooled 8.9L V8 delivers 150 kW on 3-phase natural gas, with a Power Zone 410 controller. Single-phase and propane ratings are lower, so check the numbers below.

LP Output 134 kW 1Ø / 140 kW 3Ø
NG Output 144 kW 1Ø / 150 kW 3Ø
Max Amps, 1-Phase 558 A LP / 600 A NG
Normal Load 80 dB(A)
Engine Speed 1,800 RPM
Warranty 5-Year

Best fit: large commercial and institutional buildings on 3-phase service, ideally on natural gas where the full 150 kW rating applies.

Why Choose the Generac 150kW?

Power Zone 410 Controller

A graphical multilingual controller with full system status and protections, able to support NFPA 110 with Generac’s optional accessory kit.

True Power

Less than 5% total harmonic distortion, with voltage and frequency regulation designed for sensitive electronics.

8.9L Turbocharged V8

A turbocharged and aftercooled V8 running at 1,800 RPM, with a 10.5 qt (9.9 L) crankcase.

Closed Cooling

A pressurized closed coolant system with UV/ozone-resistant hoses.

Enclosure

A sound-attenuated aluminum enclosure with a critical-grade muffler mounted inside the unit.

UL 2200 Listed

UL 2200 listed, with a smart battery charger and a 5-year limited warranty.

What Can a 150kW Generator Power?

On 3-phase natural gas the 150kW supplies 520 A at 208/120V, 451 A at 240/120V and 226 A at 480/277V. On propane those figures are 486, 421 and 210 A at 140 kW. Single-phase at 120/240V is 600 A on natural gas and 558 A on propane, with a 700 A breaker.

Full-load fuel use is 50.1 m³/hr of natural gas or 58.1 L/hr of propane. At this size the fuel service, exhaust and airflow all need to be engineered, not assumed.

  • Large commercialLarger HVAC, tenant and process loads.
  • Institutional sitesCritical systems when properly engineered.
  • 3-phase sites208/120V, 240/120V and 480/277V.
  • Fuel note150 kW only on 3-phase natural gas.
  • NFPA 110Supported with Generac’s optional accessory kit.
  • Sound80 dB(A) at normal load, at 23 ft (7 m).

Platinum sizing recommendation: We work from your load study and compare the 150kW with the 130kW. If the rating you need only applies on natural gas, we will say so early.

150kW at a Glance

It uses a Group 31, 925 CCA battery. The crankcase holds 10.5 qt (9.9 L).

  • ModelRG15090.
  • EngineGenerac 8.9L V8, turbocharged and aftercooled.
  • Electrical output150 kW 3-phase NG; 144 kW 1-phase NG.
  • Main breaker700 A (120/240V 1-phase).
  • ControllerPower Zone 410.
  • BatteryGroup 31, 925 CCA.
  • Overall size (L x W x H)143.0 x 50.5 x 68.1 in (363.3 x 128.4 x 173 cm).
  • Generator weight3,278 lb (1,487 kg).
  • Minimum concrete pad (W x L)62 x 129 in (1,554 x 3,265 mm).

Installed and Serviced Across Ontario

Generator Experts is the generator side of Platinum Electrical Contractors, a licensed Ontario electrical contractor with commercial, industrial and institutional experience since 1991. We size the 150kW for your building, handle commercial generator installation, supply the right transfer switches and concrete generator pads, and keep it ready with maintenance plans and service and repair. For cold starts, this engine uses the G009883-0 cold weather kit and, for severe cold, the G009884-0 extreme kit.

Not Sure This Is the Right Size?

We can confirm whether the 150kW fits your building or whether a smaller or larger Generac liquid-cooled generator would be a better match.

Book a Consultation

Frequently Bought Together

Installation Request
Address
Address
City
State/Province
Zip/Postal

Maximum file size: 268.44MB

How urgently do you need it?
Start Over
Thank You For Requesting a Quote!

A member of our team will be in touch shortly to discuss how we can help to meet your needs.